ORIGINAL ARTICLE
Year : 2021  |  Volume : 7  |  Issue : 1  |  Page : 31-36

Evaluating the accuracy of the SMART taylor spatial frame software – Comparison with manual radiographic analysis methods


Department of Surgical Sciences, Division of Orthopaedic Surgery, Faculty of Medicine and Health Sciences, Stellenbosch University, Cape Town, South Africa

Correspondence Address:
Prof. Nando Ferreira
Department of Surgical Sciences, Division of Orthopaedic Surgery, Faculty of Medicine and Health Sciences, Stellenbosch University, Cape Town 7505
South Africa
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jllr.jllr_5_21

Rights and Permissions

Background: The accuracy of hexapod circular external fixator deformity correction is contingent on the precision of radiographic analysis during the planning stage. The aim of this study was to compare the SMART Taylor spatial frame (TSF) in suite radiographic analysis methods with the traditional manual deformity analysis methods in terms of accuracy of correction. Methods: Sawbones models were used to simulate two commonly encountered clinical scenarios. Traditional manual radiographic analysis and digital SMART TSF analysis methods were used to correct the simulated deformities. Results: The final outcomes of all six analysis methods across both simulated scenarios were satisfactory. Any differences in residual deformity between the analysis methods are unlikely to be clinically relevant. All three SMART TSF digital analyses were faster to complete than manual radiographic analyses. Conclusion: With experience and a good understanding of the software, manual radiographic analysis can be extremely accurate and remains the gold standard for deformity analysis. In suite SMART TSF radiographic analysis is fast and precise to within clinically relevant parameters. Surgeons can with confidence trust the SMART TSF software to provide analysis and corrections that are clinically acceptable.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed993    
    Printed22    
    Emailed0    
    PDF Downloaded12    
    Comments [Add]    

Recommend this journal